HI 98196 PH/ORP/DO Portabel Meter

Update Terakhir
:
24 / 07 / 2020
Min. Pembelian
:
1 Buah

Harga

CALL
PT. Hanna Instrument indotama Kami adalah perusahaan agen tunggal di Indonesia untuk merk HANNA yang bergerak dibidang alat laboratoriun dengan spesifikasi water analisys, pengolahan air bersih, Pengolahan air tawar, pengolahan limbah dan lain-lain. Alat-alat yang dijual Checker HC Chemical Test Kits pH Meters pH/ ORP Meters Ion Selective pH/ ORP

Detail HI 98196 PH/ORP/DO Portabel Meter

pH Range 0.00 to 14.00 pH pH meter Resolution 0.01 pH pH Accuracy ±0.02 pH pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer mV Range ±600.0 mV mV Resolution 0.1 mV mV Accuracy ±0.5 mV ORP Range ±2000 mV ORP Resolution 0.1 mV ORP Accuracy ±1.0 mV ORP Calibration automatic at one custom point (relative mV) DO Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) DO Resolution 0.1%; 0.01 ppm (mg/L) DO Accuracy 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading DO Calibration automatic one or two point at 100% saturation (8.26 mg/L) and 0% saturation (0 mg/L). Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa Atmospheric Pressure Accuracy ±3 mm Hg within ±15°C from the temperature during calibration Atmospheric Pressure Calibration automatic at one custom point Temperature Range -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K Temperature Resolution 0.01 K, 0.01 °C, 0.01 °F Temperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 K Temperature Calibration automatic at one custom point Temperature Compensation automatic from -5 to 55 °C (23 to 131 °F) Logging Memory 45,000 records (continuous logging or log-on-demand of all parameters) Logging Interval one second to three hours PC Connectivity USB to PC with HI9298194 Hanna software installed Battery Type/Life 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) Environment 0 to 50°C (32 to 122°F); RH 100% (IP67) Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) Weight 400 g (14.2 oz.) Ordering Information HI98196 is supplied with HI7698196 probe, HI7698194-1 pH/ORP sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert.
Tampilkan Lebih Banyak
Kontak Kami